English
feet, if necessary.
9. After 30 minutes, turn the Auto/Off switch to the “Off” position.
10. Close the drain valve.
11. Turn the Auto/Off switch to the “Auto” position. The air receiver
will fill to “cut-out” pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up
1. Place Auto/Off switch to “Off”.
2. Close the drain valve.
3. Visually inspect air lines and fittings for leaks.
4. Check safety valve. See To Check Safety Valve under
Maintenance.
WARNING: Risk of unsafe operation. Firmly grasp air hose in
hand when installing or disconnecting to prevent hose whip.
WARNING: Risk of unsafe operation. Do not use damaged or
worn accessories.
NOTE: A regulator MUST be installed when using accessories rated
at less than 135 psi.
NOTE: The hose or accessory will require a quick connect plug if
the air outlet is equipped with a quick connect socket.
WARNING: Risk of bursting. Too much air pressure causes a
hazardous risk of bursting. Check the manufacturer’s maximum
pressure rating for air tools and accessories. The regulator outlet
pressure must never exceed the maximum pressure rating.
CAUTION: Risk of unsafe operation. Compressed air from the
unit may contain wa ter condensation and oil mist. Do not spray un l-
tered air at an item that could be damaged by moisture. Some air
tools and accessories may require ltered air. Read the in struc tions
for the air tools and accessories.
How to Start
1. Turn the Auto/Off switch to “Auto” and allow tank pressure to
build. Motor will stop when tank pressure reaches “cut-out”
pressure.
2. When the tank pressure reaches "cut-out" pressure open the
globe valve/air discharge valve.
IMPORTANT: When using regulator and other accessories refer
to the manufacturers instructions.
WARNING: Risk of bursting. If any unusual noise or vibration is
noticed, stop the compressor immediately and have it checked by
a trained service technician.
The compressor is ready for use.
Shut-down (Fig. 1)
1. Move Auto/Off switch to the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 5.
2. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in
hand when installing or disconnecting to prevent hose whip.
3. Drain the air tank,
see Draining Air Tank under Maintenance
.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
4. Allow the compressor to cool down.
5. Wipe air compressor clean and store in a safe, non-freezing
area.