DeWalt DXCMLA3706056 Use and Care Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
English
mounted.
The air compressor MUST be bolted to a level, solid concrete
surface. Use 3/8” lag screws, vibration pads and concrete
anchors. If help is needed anchoring the air compressor consult
a licensed contractor.
1. Place the air
3/8" Lag
Screw
(not supplied)
Vibration
pad
(not
supplied)
Concrete Anchor
(not supplied)
Surface Line
Shim Under
Vibration pad
(not supplied)
compressor on a
level, solid concrete
surface. Make sure
the concrete is in
good condition with
no cracks or
damage.
2. Mark the surface
using the holes in
the air compressor
feet as a template.
3. Drill holes in the
surface for the concrete anchors. Install concrete anchors.
4. Line-up holes in surface with holes in air compressor feet.
5. Place the vibration pads (not supplied) between the floor and
air compressor feet, see figure. If needed use shims to level
the unit.
6. Place the 3/8” lag screws through the air compressor feet,
vibration pads and into the anchors.
7. Torque 3/8” lag screws to 7-10 ft.-lbs (9.5-13.5 Nm).
Wiring Instructions
WARNING: Improper electrical installation of this product
may void its warranty and your re insurance. Have circuit wiring
performed by qualied personnel such as a licensed electrician
who is familiar with the current national electrical code and any
prevailing local electrical codes.
WARNING: Risk of electrical shock. Improper electrical
grounding can result in electrical shock. The wiring should be done
by a qualied electrician.
A qualified electrician needs to knows the following before wiring:
1. The amperage rating of the electrical box should be adequate.
Refer to the Specifications, in the parts manual, for this
information.
2. The supply line should have the same electrical characteristics
(voltage, cycle, phase) as the motor. Refer to the motor
nameplate, on side of motor, for this information.
NOTE: The wiring used must be rated for the motor nameplate
voltage, plus or minus 10%. Refer to local codes for recommended
wire sizes, correct wire size, and maximum wire run; undersize wire
causes high amp draw and overheating to the motor.
WARNING: Risk of electrical shock. Electrical wiring must
be located away from hot surfaces such as manifold assembly,
compressor outlet tubes, heads, or cylinders.
Grounding Instructions
This product should be connected to a metallic, permanent wiring
system, of and equipment-grounding terminal or lead on the
product.
Voltage and Circuit Protection
Refer to the Voltage and Minimum Branch Circuit Requirements
under Specifications.
CAUTION: Certain air compressors can be operated on a
15 amp circuit if the following conditions are met.
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 87 88

Comments to this Manuals

No comments