DeWalt DXCMLA3706056 Use and Care Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
14
English
SPRAY
GUN
AIR
TOOL
DRAIN
LEGS
FILTER /
MOISTURE
TRAP
DIRT
LEGS
DRAIN
VALVES
DRAIN
VALVE
LUBRICATOR
REGULATOR
GLOBE VALVE /
AIR DISCHARGE
VALVE
MAIN DISTRIBUTION AIR LINES
Slope pipe in direction of air flow.
Water condensate flows along
bottom of pipe to drain legs,
preventing it from entering feeder
lines.
REGULATOR
BALL
FILTER
FLEXIBLE
COUPLING
DRAIN
VALVE
TYPICAL
COMPRESSED AIR
DISTRIBUTION
SYSTEM
AIR FLOW
AIR FLOW
FEEDER LINES SLOPE
WITH AIR FLOW
AIR USAGE
LINES
AIR
COMPRESSOR
FILTER /
MOISTURE
TRAP
FOR BEST PERFORMANCE
the distance between the
compressor and the
moisture trap should be as
long as possible
RISK OF BURSTING. ALWAYS USE
METAL PIPING AND FITTINGS.
DRAIN
VALVES
5 MICRON
FILTER
.01 MICRON
FILTER
How to Use Your Unit (Fig 3)
How to Stop:
Set the Auto/Off switch to “Off”.
Before Starting
WARNING: Do not operate this unit until you read this instruction
manual for safety, operation and maintenance instructions.
Break-in Procedure
NOTICE: Risk of property damage. Serious damage may result if
the following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into
service and when the check valve or a complete compressor pump
has been replaced.
1. Make sure the Auto/Off switch is in the “Off” position.
2. Check oil level in pump. See Oil paragraph in the Maintenance
section for instructions.
3. Recheck all wiring. Make sure wires are secure at all terminals
connections. Make sure all contacts move freely and are not
obstructed.
4. Open the drain valve (counterclockwise) fully to permit air to
escape and prevent air pressure build up in the air tank during
the break-in period.
5. Move the Auto/Off switch to “Auto” position. The compressor
will start.
6. Run the compressor for 30 minutes. Make sure the drain valve
and all air lines are open so there is only a minimal air pressure
build-up in tank.
NOTE: After about 30 minutes, If the unit does not operate
properly, SHUT DOWN IMMEDIATELY, and contact
Product Service.
7. Check all air line fittings and connections/piping for air leaks
by applying a soap solution. Correct if necessary. NOTE: Minor
leaks can cause the air compressor to overwork, resulting in
premature breakdown or inadequate performance.
8. Check for excessive vibration. Readjust or shim air compressor
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 87 88