Technical data
DW341(K)
Power input W 550
Power output W 290
No-load speed min
-1
0-3,100
Stroke length mm 20
Cutting depth in:
- wood mm 85
- aluminium mm 20
- steel mm 10
- stainless steel alloy mm 3
Bevel angle adjustment (l/r) 0-45°
Cord length m 2.5
Weight kg 2.0
L
PA
(sound pressure) dB(A) 89
K
PA
(sound pressure uncertainty) dB(A) 3
L
WA
(sound power) dB(A) 98
K
WA
(sound power uncertainty) dB(A) 6,6
Vibration total values (triax vector sum) determined according to
EN 60745:
Vibration emission value a
h
a
hCW
= m/s² 5,5
Uncertainty K = m/s² 1,6
Vibration emission value a
h
a
hCM
= m/s² 5,3
Uncertainty K = m/s² 1,5
The vibration emission level given in this
information sheet has been measured in
accordance with a standardised test given in
EN 60745 and may be used to compare one tool
with another. It may be used for a preliminary
assessment of exposure.
WARNING: The declared vibration
emission level represents the main
applications of the tool. However if the
tool is used for different applications,
with different accessories or poorly
maintained, the vibration emission may
differ. This may significantly increase
JIGSAW
DW341(K)
the exposure level over the total
working period.
An estimation of the level of exposure
to vibration should also take into
account the times when the tool is
switched off or when it is running but
not actually doing the job. This may
significantly reduce the exposure level
over the total working period.
Identify additional safety measures to
protect the operator from the effects of
vibration such as: maintain the tool and
the accessories, keep the hands warm,
organisation of work patterns.
Fuses:
Europe 230 V tools 10 Amperes, mains
U.K. & Ireland 230 V tools 13 Amperes, in plugs
U.K. & Ireland 115 V tools 16 Amperes, in plugs
De nitions: Safety Guidelines
The definitions below describe the level of severity
for each signal word. Please read the manual and
pay attention to these symbols.
DANGER: Indicates an imminently
hazardous situation which, if not
avoided, will result in death or
serious injury.
WARNING: Indicates a potentially
hazardous situation which, if not
avoided, could result in death or
serious injury.
CAUTION: Indicates a potentially
hazardous situation which, if not
avoided, may result in minor or
moderate injury.
NOTICE: Indicates a practice not
related to personal injury which, if
not avoided, may result in property
damage.
Denotes risk of electric shock.
Denotes risk of fire.