OPERATION
WARNING: To reduce the risk of serious personal injury, turn appliance off
and disconnect appliance from power source before making any adjustments or
removing/installing attachments or accessories. An accidental start-up can cause
injury.
1. Plug the power cord into an
FIG. 4
O
N
P
appropriate outlet.
2. Turn the on/off/tool control switch
(O) to the ON position ( ).
3. Set the variable suction dial (N) to
the desired position. This feature
allows the user to control the
vacuum's power, suction and noise.
NOTE: This setting also controls
the level of suction. This is very useful in applications where the vacuum creates
unacceptable levels of drag to the work piece.
4. Follow the direction under Connecting to Power Tools to connect to the power
tool to be used.
FLOW ALARM ADJUSTMENT (FIG. 4)
Adjust the flow alarm adjustment control (P) to the correct hose (or tube) inside
diameter size or accessory diameter referring to the largest section. The chosen
diameter of the adjustment control must be equal or bigger as the largest diameter
of the used hose/tube/ accessories. The hose supplied is 32 mm inside diameter. An
acoustic alarm will sound if the flow rate falls below 20 m/s. The system has a time
delay to reduce unintended alarms.
CONNECTING TO POWER TOOLS (FIG. 1, 4, 5)
WARNING: Only use the outlet (M) for purposes specified in the instructions.
1. Plug the vacuum power cord into an appropriate outlet.
2. Plug the power tool into the outlet (M).
NOTE: See Power connection data of power tool under Technical Data for the
power allowance of the tool to be plugged into the outlet (M).
3. Turn on/off/tool control switch (O) to the ACTIVATION position .
This allows the vacuum to be turned on and off automatically by the power tool.
NOTE: The vacuum cleaner starts automatically within 0.5 seconds and
continues to run for 15 seconds after the power tool has been turned off.
4. To switch back to manual mode, turn the on/off/tool control switch (O) to the
ON position (
). In manual mode the tool and the vacuum are turned on and off
independent of each other.
U
U
V
FIG. 5
G
5. Your DEWALT construction dust extractor is fitted with the DEWALT AirLock
connection system. The AirLock allows for a fast, secure connection between the
suction hose (G) and power tool. The AirLock connector (V) connects directly
to DEWALT compatable tools or through the use of an AirLock adapter (available
from your local DEWALT supplier). Refer to the Accessories section for details on
available adapters.
NOTE: If using an adapter, ensure it is firmly attached to the tool outlet before
following the steps below.
a. Ensure the collar on the AirLock connector is in the unlock position. Align
notches (U) on collar and AirLock connector as shown for unlock and lock
positions.
b. Push the AirLock connector onto the adapter connector point.
c. Rotate the collar to the locked position.
NOTE: The ball bearings inside collar lock into slot and secure the connection.
The power tool is now securely connected to the dust extractor.