D279059B Dust extraction beater bar kit
TROUBLESHOOTING
PROBLEM SOLUTION
Motor does not run Check power cord, plugs and outlet.
Ensure the on/off /tool control switch is in the ON
position (
).
Suction capacity decreases Remove blockages in the suction nozzle, suction
tube, suction hose or filters.
Replace the paper or fleece bag.
Check for proper installation of the filters.
Clean or replace the filters.
Empty canister, refer to Empty Canister under
Operation.
Vacuum stops running Thermal overload has been tripped:
1. Turn the vacuum off and disconnect vacuum
cleaner from power source.
2. Empty the canister, if needed.
3. Allow the unit to cool.
4. Plug the power cord into an appropriate outlet
and turn on/off/tool control switch to the ON
position (
) to test. If vacuum will not restart
call 1800 444 224 or (NZ) 0800 339 258.
PROBLEM SOLUTION
Dust comes out while
vacuuming
Check for proper installation of the filters.
Ensure filters are not damaged; replace if necessary.
Ensure filter seals are in place and are secure.
Automatic filter cleaning is
not working
Listen for the solenoid clicking to ensure the filter
cleaning mechanism is working.
Power tool does not turn
on.
Ensure the on/off/tool control switch is in the
ACTIVATION position
.