English
OPERATING PROCEDURES
WARNING: Do not operate this unit until you read and understand
this instruction manual for safety, operation and maintenance
instructions.
Start-up (Fig. 1)
1. Follow Pre-Start Checklist under Preparation for Use.
2. Move the On/Off switch to the ON position and allow tank pres-
sure to build. Motor will stop when tank pressure reaches
cut-out pressure.
CAUTION: Risk of unsafe operation. Compressed air from the
unit may contain wa ter condensation. Do not spray un fil tered air
at an item that could be damaged by moisture. Some air op er ated
tools or de vic es may require filtered air. Read the in struc tions for
the air tool or device.
3. Adjust regulator (D) to desired setting. See Regulator under
Features.
Shut-down (Fig. 1)
1. Move On/Off switch (A) is in the OFF position. NOTE: If finished
using compressor, follow Steps 2–6.
NOTE: When the unit has been turned off, it is normal to hear a
short hiss of air being released.
2. Turn regulator knob (D) counterclockwise until fully closed. Ensure
regulated pressure gauge reads 0 psi.
3. Remove hose and accessory.
NOTE:
Always turn off and unplug unit when not in use.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank,
see Draining Air Tank under Maintenance
.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will con-
dense in air tank. If not drained, water will corrode and weaken the
air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
The following procedures must be followed when maintenance or
service is performed on the air compressor.
1. Ensure On/Off switch is in the OFF position.
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
NOTE: All compressed air systems contain maintenance parts (e.g.,
oil, filters, separators) that are periodically replaced. These used parts
may contain substances that are regulated and must be disposed of in
accordance with local, state, and federal laws and regulations.
NOTE: Take note of the positions and locations of parts during
disassembly to make reassembly easier.
NOTE: Any service operations not included in this section should
be performed by a D
e
WALT factory service center or a D
e
WALT
authorized service center.
Maintenance Chart
Procedure Before Each
Use
Daily or after
each use
See tank
warning label
Check safety valve
X
Drain air tank
X
Remove tank from
service
X
1
1- For more information, call 1-800-4-D
e
WALT (1-800-433-9258)
Page view 11